Model |
S-320-5 |
S-320-7.5 |
S-320-12 |
S-320-13.5 |
S-320-15 |
S-320-24 |
S-320-27 |
S-320-48 | |||
Output |
DC Voltage |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
27V |
48V | ||
Voltage Tolerance |
±2% |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% | |||
Rated Current |
50A |
36A |
25A |
22A |
20A |
12.5A |
11A |
6.5A | |||
Current Range |
0-50A |
0-36A |
0-25A |
0-22A |
0-20A |
0-12.5A |
0-11A |
0-6.5A | |||
Rated Power |
250W |
270W |
300W |
297W |
300W |
300W |
297W |
312W | |||
Ripple & Noise |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
240mVp-p | |||
DC Voltage Adj. Range |
-10%,+14% |
±20% |
-16%,+10% |
-12%,+11% |
-10%,+20% |
-16%,+10% |
-4%,+18% |
-15%,+17% | |||
Setup, Rise, Hold time |
2s,20ms,20ms full load | ||||||||||
Input |
Voltage Range |
88~132 VAC/176~264VAC 47~63 Hz;selected by switch 248~370VDC | |||||||||
AC Current |
6A/115 V 3.5A/ 230 V | ||||||||||
Efficiency |
77% |
80% |
82% |
83% |
84% |
86% |
86% |
87% | |||
Inrush Current |
Cold start 20A/115V 40A/230V | ||||||||||
Leakage Current |
<3.5mA/240VAC | ||||||||||
Protection |
Over Load |
105%~135% | |||||||||
Protection type:hiccup mode,recovers automatically after fault condition is removed | |||||||||||
Over Voltage |
115%~135% | ||||||||||
Protection type:hiccup mode,recovers automatically after fault condition is removed | |||||||||||
FAN Control O.T.P |
RT1≥65℃FAN ON,≤55℃FAN OFF,≥70℃ output shut down (5~15V) | ||||||||||
RT1≥70℃FAN ON,≤65℃FAN OFF,≥80℃ output shut down(24~48V) | |||||||||||
Environment |
Working Temp. & Humidity |
-10℃~+60℃;20%~90 %RH | |||||||||
Storage Temp. & Humidity |
-20℃~+85℃;10%~95 %RH | ||||||||||
Vibration |
10~500Hz,2G 10min./1cycle,period for 60min,each along X,Y,Z axes | ||||||||||
Safety |
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | ||||||||||
Standards |
Safety Standard |
Design refer to UL1950 | |||||||||
EMC Standard |
Design refer to EN55022,EN55024,EN61000 | ||||||||||
Others |
Weight |
1.08Kg | |||||||||
Packing |
12pcs/13.5Kg/0.93CUFT | ||||||||||
Remarks |
1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ&47μparallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpment must be re-confirmed that it still meets EMC directives. 5. Concrete output current see Derating Curve. |