T-60-we are the professional switching power supply  supplier,switching power supply have many different types.pls send enquiry of switching power supply to sales@chnfavor.com
See larger image -Please click product image

T-60

We are the professional switching power supply supplier,good quality with competitive price,welcome to contact us for enquiry.
T-60 Description

Features:
High efficiency,high reliability
Universal AC input/full range
Protections:Short circuit/over load/over voltage
Cooling by free air convection
LED indicator for power on
Fixed switching frequency at 50KHz
1 year warranty
Dimension : 159*97*38mm(L*W*H)



Shell code:H003

Model

T-60A

T-60B

T-60C

CH1

CH2

CH3

CH1

CH2

CH3

CH1

CH2

CH3

Output

DC Voltage

5V

12V

-5V

5V

12V

-12V

5V

15V

-15V

Voltage Tolerance

±2%

±6%

±6%

±2%

±6%

±6%

±2%

±6%

±6%

Rated Current

5A

2.5A

0.5A

5A

2.5A

0.5A

5A

2A

0.5A

Current Range

0.5-7A

0.2-3.5A

0-1A

0.5 -7A

0.2-3.5A

0-1A

0.5-7A

0.2-3A

0-1A

Rated Power

57.5W

61W

62.5W

Ripple & Noise

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

DC Voltage Adj. Range

CH1:-5%,+10%

Setup, Rise, Hold time

300ms,50ms,10ms/230VAC 800ms, 50ms, 10ms/115VAC full load

Input

Voltage Range

85~264 VAC 47-63Hz;120~370VDC

AC Current

2A/115 V 1A/ 230 V

Efficiency

69%

72%

72%

Inrush Current

Cold start 30A/115V 60A/230V

Leakage Current

<3.5mA/240VAC

Protection

Over Load

105%~150%

Protection type:Hiccup mode,recovers automatically after fault condition is removed.

Over Voltage

5V:115%~135%

Protection type:Hiccup mode, re-power on to recover

Environment

Working Temp. & Humidity

-10℃~+60℃;20%~90 %RH

Storage Temp. & Humidity

-20℃~+85℃;10%~95 %RH

Vibration

10~500Hz,2G 10min./1 cycle,period for 60min,each along X,Y,Z axes

Safety

Withstand Voltage

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG : 100M Ohms/500VDC

Standards

Safety Standard

Design refer to UL1012,UL60950, TUV EN60950

EMC Standard

EN55022,EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024

Others

Weight

0.55Kg

Packing

30pcs/17Kg/0.99 CUFT

Remark

1. All parameter not specially mentioned are measured at 230VACinput,rated load and 25℃ of ambient temperature.
2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ&47μparallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equpment must be re-confirmed that it still meets EMC directives.
5. Concrete output current see Derating Curve.

 