Model |
S-145-5 |
S-145-7.5 |
S-145-12 |
S-145-15 |
S-145-24 |
S-145-48 | |||
OUTPUT |
DC Voltage |
5V |
7.5V |
12V |
15V |
24V |
48V | ||
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% | |||
Rated Current |
25A |
18A |
12A |
9.6A |
6A |
3A | |||
Current Range |
0-25A |
0-18A |
0-12A |
0-9.6A |
0-6A |
0-3A | |||
Rated Power |
125W |
135W |
144W |
144W |
144W |
144W | |||
Ripple & Noise |
100mVp-p |
120mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
240mVp-p | |||
DC Adjustment Range |
±10% |
-20%,+10% |
-12%,+10% |
-12%,+10% |
-12%,+16% |
-10%,+15% | |||
Setup,Rise,Hold Time |
100ms,50ms,20ms at full load | ||||||||
INPUT |
Voltage Range |
88~132 VAC/176~264VAC 47~63 Hz; | |||||||
AC Current |
3.2A/115 V 1.6A/ 230 V | ||||||||
Efficiency |
78% |
80.5% |
80.5% |
81% |
83.5% |
82% | |||
Inrush Current |
Cold start 35A/230VAC | ||||||||
Leakage Current |
<3.5 mA/240VAC | ||||||||
PROTECTION |
Over Load |
115%~165% | |||||||
Protection type: Shut down o/p voltage, re-power on to recover | |||||||||
Over Voltage |
115%~135% | ||||||||
Protection type: Shut down o/p voltage, re-power on to recover | |||||||||
ENVIRONMENT |
Working Temp., Humidity |
-10℃~+60℃;20%~90 %RH | |||||||
Storage Temp., Humidity |
-20℃~+85℃;10%~95 %RH | ||||||||
Vibration |
10~500Hz,2G 10min./1cycle,period for 60min, each along X, Y, Z axes | ||||||||
SAFETY |
Withstand Voltage |
I/P-O/P: 1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC | |||||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||||||
STANDARD |
Safety Standard |
Design refer to UL1012 | |||||||
EMC Standard |
Design refer to EN55022,IEC801-2,3,4 | ||||||||
OTHERS |
Weight |
0.71Kg | |||||||
Packing |
30pcs/22kg/1.22CUFT | ||||||||
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ &47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation |