Model |
S-100-3 |
S-100-5 |
S-100-7.5 |
S-100-12 |
S-100-15 |
S-100-18 |
S-100-24 |
S-100-27 |
S-100-48 | |||
Output |
DC Voltage |
3V |
5V |
7.5V |
12V |
15V |
18V |
24V |
27V |
48V | ||
Voltage Tolerance |
±2% |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% | |||
Rated Current |
20A |
20A |
13.6A |
8.5A |
6.7A |
5.6A |
4.5A |
3.7A |
2A | |||
Current Range |
0-20A |
0-20A |
0-13.6A |
0-8.5A |
0-6.7A |
0-5.6A |
0-4.5A |
0-3.7A |
0-2A | |||
Rated Power |
60W |
100W |
102W |
102W |
100.5W |
100.8W |
108W |
99.9W |
96W | |||
Ripple & Noise |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
150mVp-p | |||
DC Voltage Adj. Range |
-5%,+10% |
-5%,+10% |
±10% |
±10% |
±10% |
±10% |
±10% |
-4%,+18% |
±10% | |||
Setup, Rise, Hold time |
200ms,80ms,20ms at full load | |||||||||||
Input |
Voltage Range |
85~132 VAC/180~264VAC 47~63 Hz;selected by switch 255~370VDC | ||||||||||
AC Current |
2.4A/115 V 1.2A/ 230 V | |||||||||||
Efficiency |
70% |
78% |
80% |
81% |
81% |
82% |
84% |
84% |
84% | |||
Inrush Current |
Cold start 30A/115V 60A/230V | |||||||||||
Leakage Current |
<1 mA/240VAC | |||||||||||
Protection |
Over Load |
115%~165% | ||||||||||
Protection type: Shut down o/p voltage, Repower on to recover. | ||||||||||||
Environment |
Working Temp. & Humidity |
-10℃~+60℃;20%~90 %RH | ||||||||||
Storage Temp. & Humidity |
-20℃~+85℃;10%~95 %RH | |||||||||||
Vibration |
10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||||||||||
Safety |
Withstand Voltage |
I/P-O/P:1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC | ||||||||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG100M Ohms/500VDC | |||||||||||
Standards |
Safety Standard |
Design refer to UL1012 | ||||||||||
EMC Standard |
Design refer to FCC Part15 J Conduction Class B | |||||||||||
Others |
Weight |
0.62Kg | ||||||||||
Packing |
30pcs/19Kg/1.22CUFT | |||||||||||
Remarks |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ &47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation |