Features: |
Shell code:H003 |
Model |
T-50A |
T-50B |
T-50C |
T-50D | ||||||||||||
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 | |||||
Output |
DC Voltage |
5V |
12V |
-5V |
5V |
12V |
-12V |
5V |
15V |
-15V |
5V |
12V |
24V | |||
Voltage Tolerance |
±2% |
±5% |
±5% |
±2% |
±5% |
±5% |
±2% |
±5% |
±5% |
±2% |
±6% |
±6% | ||||
Rated Current |
7A |
1A |
1A |
5A |
1A |
1A |
4A |
1A |
1A |
3A |
1A |
1A | ||||
Current Range |
0.6-7A |
0.2-1A |
0.2-1A |
0.6-5A |
0.2-1A |
0.2-1A |
0.6-4A |
0.2-1A |
0.2-1A |
0.6-4A |
0.2-1.2A |
0.2-1.2A | ||||
Rated Power |
52W |
49W |
50W |
51W | ||||||||||||
Ripple & Noise |
100 mV |
100 mV |
100 mV |
100 mV |
100 mV |
100 mV |
100 mV |
100 mV |
100 mV |
50 mV |
120 mV |
120 mV | ||||
DC Voltage Adj. Range |
CH1: -5%,+10% | |||||||||||||||
Setup, Rise, Hold time |
200ms,100ms,16ms full load | |||||||||||||||
Input |
Voltage Range |
85~132 VAC / 170~264 VAC 47-63Hz;selected by switch 240~370VDC | ||||||||||||||
AC Current |
1.6A/115 V0.8A/ 230 V | |||||||||||||||
Efficiency |
66% |
69% |
71% |
72% | ||||||||||||
Inrush Current |
Cold start 20A/115V 40A/230V | |||||||||||||||
Leakage Current |
<0.5mA/240VAC | |||||||||||||||
Protection |
Over Load |
105%~150% | ||||||||||||||
Protection type:shut down o/p voltage,fold back current limiting, recovers automatically after fault condition is removed. | ||||||||||||||||
Environment |
Working Temp. & Humidity |
-10℃~+60℃;20%~90 %RH | ||||||||||||||
Storage Temp. & Humidity |
-20℃~+85℃;10%~95 %RH | |||||||||||||||
Vibration |
10~500Hz,2G 10min./1 cycle,period for 60min,each along X,Y,Z axes | |||||||||||||||
Safety |
Withstand Voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||||||||||
Isolation Resistance |
I/P-O/P, I/P-FG. O/P-FG: 100M Ohms/500VDC | |||||||||||||||
Standards |
Safety Standard |
Design refer to UL1012 | ||||||||||||||
Others |
Weight |
0.54Kg | ||||||||||||||
Packing |
24pcs/14Kg/0.75CUFT | |||||||||||||||
Remark |
1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ&47μparallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Concrete output current see Derating Curve. |