Fetures: |
Shell code:H003 |
Model |
D-50A |
D-50B | |||
CH1 |
CH2 |
CH1 |
CH2 | ||
Output |
DC Voltage |
5V |
12V |
5V |
24V |
Voltage Tolerance |
±2% |
+5,-8% |
±2% |
±8% | |
Rated Current |
6A |
2A |
6A |
1A | |
Current Range |
1-6A |
0.3-2A |
1-6A |
0.2-1A | |
Rated Power |
54W |
54W | |||
Ripple & Noise |
50mVp-p |
100mVp-p |
50mVp-p |
100mVp-p | |
DC Voltage Adj. Range |
CH1:-5%,+10% | ||||
Setup, Rise, Hold time |
200ms,50ms,20ms full load | ||||
Input |
Voltage Range |
85~132 VAC/170~264VAC 47~63 Hz;selected by switch 240~370VDC | |||
AC Current |
1.3A/115VAC0.65A/230VAC | ||||
Efficiency |
73% |
73% | |||
Inrush Current |
Cold start 18A/115V 36A/230V | ||||
Leakage Current |
<0.5mA/240VAC | ||||
Protection |
Over Load |
105%~150% | |||
Protection type:Shut down o/p voltage,recovers automatically after fault condition is removed. | |||||
Environment |
Working Temp. & Humidity |
-10℃~+60℃;20%~90 %RH | |||
Storage Temp. & Humidity |
-20℃~+85℃;10%~95 %RH | ||||
Vibration |
10~500Hz,2G 10min./1cycle, period for 60min,each along X,Y,Z axes | ||||
Safety |
Withstand Voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
Isolation Resistance |
I/P-O/P; I/P-FG; O/P-FG:100M Ohms/500VDC | ||||
Standards |
Safety Standards |
Refer to UL1012 | |||
EMC Standards |
Design refer to FCC Part15 J Conduction | ||||
Others |
Weight |
0.53Kg | |||
Packing |
24pcs/13.6Kg/0.75CUFT | ||||
Remark |
1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. |