Features: |
Shell code:H036 |
Model |
HDR-120-12 |
HDR-120-24 |
HDR-120-48 | |
OUTPUT |
DC Voltage |
12V |
24V |
48V |
Voltage Tolerance |
±2% |
±1% |
±1% | |
Rated Current |
10A |
5A |
2.5A | |
Current Range |
0-10A |
0-5A |
0-2.5A | |
Rated Power |
120W |
120W |
120W | |
Ripple & Noise |
100mVp-p |
120mVp-p |
150mVp-p | |
DC Adjustment Range |
12-14V |
24-28V |
48-53V | |
Setup, Rise Time |
500ms,70ms/230VAC at full load500ms,70ms/115VACat full load | |||
Hold Time |
36ms/230VAC32ms/115VAC at full load | |||
INPUT |
Voltage Range |
85~264 VAC/176~264VAC47~63 Hz;selected by 120~370VDC | ||
AC Current |
2.6 A/115 V 1.6A/ 230 V | |||
Efficiency |
81% |
83% |
84% | |
Inrush Current |
Cold start 20A/115V 40A/230V | |||
Leakage Current |
<3.5mA/240VAC | |||
PROTECTION |
Over Load |
105%~150% | ||
Protection type: Shut down O/P voltage, recovers automatically after fault condition is removed | ||||
Over Voltage |
120%~140% | |||
Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed | ||||
OVER TEMP. |
85℃±5℃(TSW1) |
90℃±5℃(TSW1) |
90℃±5℃(TSW1) | |
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | ||||
ENVIRONMENT |
Working Temp., Humidity |
-10℃~+60℃;20%~90 %RH | ||
Storage Temp., Humidity |
-20℃~+85℃;10%~95 %RH | |||
Vibration |
10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||
SAFETY |
Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC | ||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC | |||
STANDARD |
Safety Standard |
Design refer to UL508,UL60950-1,TUV EN60950-1 | ||
EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2) | |||
OTHERS |
Weight |
0.79Kg | ||
Packing |
16pcs/14Kg/1.22CUFT | |||
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. |