Features: |
Shell code:H035 |
Model |
HDR-75-12 |
HDR-75-24 |
HDR-75-48 | |
OUTPUT |
DC Voltage |
12V |
24V |
48V |
Voltage Tolerance |
±2% |
±1% |
±1% | |
Rated Current |
6.3A |
3.2A |
1.6A | |
Current Range |
0-6.3A |
0-3.2A |
0-1.6A | |
Rated Power |
76W |
76.8W |
76.8W | |
Ripple & Noise |
100mVp-p |
150mVp-p |
240mVp-p | |
DC Adjustment Range |
±10% |
±10% |
±10% | |
Setup, Rise Time |
1000ms,60ms/230VAC at full load1800ms,60ms/115VACat full load | |||
Hold Time |
60ms/230VAC12ms/115VAC at full load | |||
INPUT |
Voltage Range |
85~264 VACselected by switch 47~63 Hz;120~370VDC | ||
AC Current |
1.6 A/115 V 0.96A/ 230 V | |||
Efficiency |
81% |
82% |
83% | |
Inrush Current |
Cold start 20A/115V 40A/230V | |||
Leakage Current |
<1mA/240VAC | |||
PROTE |
Over Load |
105%~150% | ||
Protection type: Shut down O/P voltage, recovers automatically after fault condition is removed | ||||
Over Voltage |
120%~140% | |||
Protection type: Shut down O/P voltage, recovers automatically after fault condition is removed | ||||
ENVIRON |
Working Temp., Humidity |
10℃~+60℃;20%~90 %RH | ||
Storage Temp., Humidity |
-20℃~+85℃;10%~95 %RH | |||
Vibration |
10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||
SAFETY |
Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC | ||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC | |||
STANDARD |
Safety Standard |
Design refer to UL508,TUV EN60950-1 | ||
EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2 | |||
OTHERS |
Weight |
0.54Kg | ||
Packing |
16pcs/10Kg/1.22CUFT | |||
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. |